Racks

The rack model represents a physical two- or four-post equipment rack in which devices can be installed. Each rack must be assigned to a site, and may optionally be assigned to a location within that site. Racks can also be organized by user-defined functional roles. The name and facility ID of each rack within a location must be unique.

Rack height is measured in rack units (U); racks are commonly between 42U and 48U tall, but NetBox allows you to define racks of arbitrary height. A toggle is provided to indicate whether rack units are in ascending (from the ground up) or descending order.

Each rack is assigned a name and (optionally) a separate facility ID. This is helpful when leasing space in a data center your organization does not own: The facility will often assign a seemingly arbitrary ID to a rack (for example, "M204.313") whereas internally you refer to is simply as "R113." A unique serial number and asset tag may also be associated with each rack.

Fields

Site

The site to which the rack is assigned.

Location

The location within a site where the rack has been installed (optional).

Name

The rack's name or identifier. Must be unique to the rack's location, if assigned.

Status

Operational status.

Tip

Additional statuses may be defined by setting Rack.status under the FIELD_CHOICES configuration parameter.

Role

The functional role fulfilled by the rack.

Facility ID

An alternative identifier assigned to the rack e.g. by the facility operator. This is helpful for tracking datacenter rack designations in a colocation facility.

Serial Number

The unique physical serial number assigned to this rack.

Asset Tag

A unique, locally-administered label used to identify hardware resources.

Type

A rack can be designated as one of the following types:

  • 2-post frame
  • 4-post frame
  • 4-post cabinet
  • Wall-mounted frame
  • Wall-mounted cabinet

Width

The canonical distance between the two vertical rails on a face. (This is typically 19 inches, however other standard widths exist.)

Height

The height of the rack, measured in units.

Starting Unit

The number of the numerically lowest unit in the rack. This value defaults to one, but may be higher in certain situations. For example, you may want to model only a select range of units within a shared physical rack (e.g. U13 through U24).

Outer Dimensions

The external width and depth of the rack can be tracked to aid in floorplan calculations. These measurements must be designated in either millimeters or inches.

Mounting Depth

The maximum depth of a mounted device that the rack can accommodate, in millimeters. For four-post frames or cabinets, this is the horizontal distance between the front and rear vertical rails. (Note that this measurement does not include space between the rails and the cabinet doors.)

Weight

The numeric weight of the rack, including a unit designation (e.g. 10 kilograms or 20 pounds).

Maximum Weight

The maximum total weight capacity for all installed devices, inclusive of the rack itself.

Descending Units

If selected, the rack's elevation will display unit 1 at the top of the rack. (Most racks use ascending numbering, with unit 1 assigned to the bottommost position.)